SPECIFICATIONS
| Designation | Optical touch switch | |
| Model No. | SW-101 | |
| Sensing method | Thru-beam type photoelectric sensor (2 beam axes) | |
| Applicable standards | CSA 22.2 No.14, CSA 22.2 No.0.8, ANSI / NFPA 79, UL 508, EN 60947-5-2 (EMC only) | |
| Power supply | 12 to 24 V DC ±10% Ripple P-P 10 % or less | |
| Current consumption | 100 mA or less (excluding external connection load) | |
| Outputs | Semiconductor Photo-MOS relay output x 3 ・Maximum load current: 100 mA ・Applied voltage: 30 V DC or less (between output and +V) ・Residual voltage: 1.5 V or less (at 100 mA load current) |
|
| Output operation | Output 1: When an object is detected (beam is interrupted): OFF / When an object is not detected (beam is received): ON Output 2, 3: When an object is detected (beam is interrupted): ON / When an object is not detected (beam is received): OFF |
|
| Short-circuit protection | Incorporated | |
| Response time | 100 ms or less when an object is detected, 50 ms or less when an object is not detected | |
| Time-out function | Switched either effective or ineffective by short-circuiting terminals (ineffective when short-circuited) | |
| External input | 0 to +1 V or +10 V to +V: Valid (External input indicator lights up) +4 to +6 V or Open: Invalid (External input indicator lights off) |
|
| Power indicator (POWER) | Green LED (lights up when the power is ON) | |
| Operation indicator (OPE.) | Green LED (lights up when an object is detected) | |
| External input indicator 1 | Green LED (lights up when external input 1 is valid) | |
| External input indicator 2 | Orange LED (lights up when external input 2 is valid) | |
| Fault indicator (FAULT) | Yellow LED (blinks or lights up when fault occurs) | |
| Protection | IP65 (IEC) TYPE 1 (UL 50) (excluding terminal part) | |
| Ambient temperature | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed), Storage: -30 to +70 ℃ -22 to +158 ℉ |
|
| Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH | |
| Ambient illuminance | Incandescent light: 3,000 lx at the light-receiving face | |
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | |
| Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | |
| Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in amplitude in X, Y and Z directions for two hours each | |
| Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each | |
| Removable-type terminals | Connector: 3.5 mm 0.138 in pitch, 2-level socket; 12 pins Terminal part: 3.5 mm 0.138 in pitch spring gauge terminals; 6 pins x 2 (FMC1,5 / 6-ST-3,5 manufactured by Phoenix Contact) |
|
| Cable | 0.2 to 1.5 mm2 [including single wire or ferrule (sleeve)] | |
| Maximum cable length | Up to 20 m 65.617 ft (for cables from 0.2 to 0.3 mm2) Up to 100 m 328.084 ft (for cables from 0.3 to 1.5 mm2) |
|
| Material | Enclosure: Polycarbonate, Polyester, Nut: PBT, O-ring: Silicone rubber | |
| Weight | Net weight: 130 g approx., Gross weight: 200 g approx. | |
Note:
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.