DESCRIPTION
Easy installation using a hexagonal wrench
Breakthrough construction: Hexagonal wrench installation
Obstructions can be avoided and installation from above can be done much more easily using a hexagonal wrench. This also eliminates wasted installation space and contributes to a smaller installation footprint.
Flexible design! Sensor heads can be embedded
Installation in narrow spaces is possible.
Because the bolts can be turned from directly above, embedding the sensor heads into narrow spaces is possible. In addition, the flat installation leaves no worries for danger of objects striking against the sensor and damaging it.
Quick maintenance
One sensor can be removed from between others.
During maintenance, the sensor head needed to be removed can be easily removed from directly above.
Mounting space-saving

Space saving during installation.
Because the dead zone caused by the nut is eliminated, the narrowed-down thickness after installation contributes to space saving.
Separate analog voltage output for each sensor head

The analog voltage output from the sensor head can be picked up directly.
Reduced tact time

Suitable for high-speed applications.
Fastest response time of 500 μs contributes to even greater productivity.
3-color display lets you view the controller status at a glance

The main display color switches between green and red in accordance with the ON / OFF status of output during RUN mode. In addition, the display always appears orange while setting is in progress, so that the status of the controller can be viewed at a glance.
The controller's setting operation mode has a 3-level configuration to suit the frequency of use
The setting levels are clearly separated into "RUN mode" for operation settings that are carried out daily, "MENU SETTING mode" for basic settings, and "PRO mode" for special and detailed setting. These make setting operations easy to understand and easy to carry out.
Copy function reduces man-hours and human error
Controllers can be connected to a master controller one by one, and a copy of the setting details for the master controller can be transmitted as data to the slave controllers. If making the same settings for multiple controllers, this prevents setting errors from occurring with the other controllers and also reduces the number of changes required to instruction manuals when equipment designs are changed.
Sensor head auto-recognition
The controller will automatically recognize sensor heads when they are connected, even for sensor heads with different rated pressure ranges. There is no need to use the controller to change settings.
Equipped with independent two output and three output modes
Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Two comparative outputs are provided, so that one of the outputs can be used as a warning output. In addition, if an output is not being used, it can be disabled.
Equipped with auto-reference / remote zero-adjustment functions
If the reference pressure of the device changes, the autoreference function partially shift the comparative output judgment level by the amount that the reference pressure shifts, and the remote zero-adjustment function can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are desired.
Response time can be changed
The response time can be changed in 12 levels from 500 μs to 5,000 ms. This prevents chattering and incorrect operation due to sudden changes in pressure.
Setting details can be understood at a glance

The DPC-100 setting details appear in the digital display. Because the settings are in numeric form that can be easily understood, it is useful for times such as when receiving technical support by telephone.
Energy-saving design! Equipped with an ECO mode
This mode lowers the display luminance to cut power consumption by approximately 30 %. The displays can also be turned off completely to achieve a power saving of approximately 40 %.
Display refresh rate can be varied
The display refresh rate for the digital displays can be changed to one of three settings: 250 ms, 500 ms or 1,000 ms. Flickering of the display can be reduced by making the display refresh rate longer.
Tight installation to panels is possible

An exclusive mounting bracket (MS-DP1-2) that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available.
An exclusive mounting bracket (MS-DP1-6) that supports tight installation

Space saving can also be obtained if an L-shaped mounting bracket is used.