DESCRIPTION
The dual display means that the "current value" and the "threshold value", it makes direct setting of threshold value

Equipped with a 30 mm 1.181 in square compact-sized dual display. Because the current value and the threshold value can be checked at the same time, the threshold value can be set and checked smoothly without having to switch screen modes. ON / OFF operations are still carried out while the threshold values are being set, so setting to the same sensitivity as dial control-type sensors is possible. And naturally a key lock function is also equipped.
3-color display (Red, Green, Orange)
The main display changes color in line with changes in the status of output ON / OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be understood easily, and operating errors can be reduced.
Readable digital display

12 segments are used and an alphanumeric display has been adopted. This improves visual checking of letters and numbers.
All models in the line-up are compound pressure types

No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased.
Realizes high performance [Low pressure type]
![Realizes high performance [Low pressure type]](/en/products/pressure/dp-100/images/dp-100_1_7.jpg)
The low pressure type displays measurements in 0.1 kPa at a resolution of 1/2,000 and has a response time of 2.5 ms (variable up to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 % F.S. repeatability, giving it high performance.
Copy function reduces man-hours and human error
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to the other sensors. If making the same settings for multiple sensors, this prevents setting errors from occurring with the other sensors and also reduces the number of changes required to instruction manuals when equipment designs are changed.
The sensor's setting operation mode has a 3-level configuration to suit the frequency of use

The setting levels are clearly separated into "RUN mode" for operation settings that are carried out daily, "MENU SETTING mode" for basic settings, and "PRO mode" for special and detailed setting. These make setting operations easy to understand and easy to carry out.
■RUN mode
Settings such as threshold value adjustment and key lock operation can be carried out while the sensor is operating.
■MENU SETTING mode
Basic settings such as output mode setting and NO / NC switching can be carried out.
■PRO mode
High-level function settings such as hysteresis adjustment and the copy function can be carried out.
Equipped with independent dual output and three output modes
Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the comparative outputs can even be used for alarm output. In addition, if an output is not being used, it can be disabled.
Cable can be connected with one-touch connection

The accessory connector attached cable (2 m 6.562 ft) can be connected easily with one-touch connection.
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available.
Please see P.600 for information about the recommended commercially
available connectors.
Short pressure port type is lightweight and takes up little space [DP-10□-M]
Compact size with a depth of only 30 mm 1.181 in, so that it can easily fit into narrow spaces.
Further, 10 g lighter than standard types. This reduces the loads on movable parts such as robot arms.
Switch-over of the pressure port or flat mounting on the wall is possible (For short pressure port type)
By mounting the flat attachment to DP-10□-M, pressure port and cable can now be pulled out in downward, left or right directions. Flat mountimg on surfaces such as the wall is made possible.
Rc1/8 conversion bushing improves compatibility with the previous model (For short pressure port type)

By equipping the push-in converter with DP-10□-M, pressure port can be converted from M5 female thread to Rc1/8 female thread.
Bore diameter conversion to the DP2/DP3 series is possible.
Inquiry
Catalog request |
|
Inquiry |
|
Worldwide sales & service network |